Complete atrioventricular block after atrial flow regulator implantation in a 5 kg infant

Cardiol Young. 2024 Oct 3:1-3.doi: 10.1017/S1047951124025988. Online ahead of print.

Céline Grunenwald Gronier 1 Nadir Benbrik 1 Alban-Elouen Baruteau 1 2 3 4 PMID: 39358845 DOI: 10.1017/S1047951124025988

Abstract

The atrial flow regulator is a new self-expandable double-disc fenestrated device providing a calibrated inter-atrial communication. Paediatric reports are scarce. We herein describe a case of complete atrioventricular block complicating the exemption use of an atrial flow regulator in a 5-kg infant with transposition of the great arteries, ventricular septal defect, and right ventricular outflow tract obstruction.

Keywords: atrial flow regulator; atrioventricular block; blood mixing; transposition of the great arteries.